Mostra el registre parcial de l'element

dc.contributorInternational Conference on Non-Linear Speech Processing NOLISP (2013 : Bèlgica)
dc.contributorUniversitat de Vic. Escola Politècnica Superior
dc.contributorUniversitat de Vic. Grup de Recerca en Tecnologies Digitals
dc.contributor.authorMartí i Puig, Pere
dc.contributor.authorSolé-Casals, Jordi
dc.contributor.authorMasferrer Caralt, Gerard
dc.contributor.authorGallego Jutglà, Esteve
dc.date.accessioned2014-01-10T12:10:18Z
dc.date.available2014-01-10T12:10:18Z
dc.date.created2013
dc.date.issued2013
dc.identifier.citationMartí-Puig, P., Solé-Casals, J., Masferrer, G., & Gallego-Jutglà, E. (2013). Towards a low-complex breathing monitoring system based on acoustic signals. Lectures Notes in Computer Scince, 7911 LNAI pp. 128-135ca_ES
dc.identifier.issn0302-9743
dc.identifier.urihttp://hdl.handle.net/10854/2624
dc.description.abstractMonitoring the breathing is required in many applications of medical and health fields, but it can be used also in new game applications, for example. In this work, an automatic system for monitoring the breathing is presented. The system uses the acoustic signal recorded by a standard microphone placed in the area of the nostrils. The system is based on a low-complex signal parameterization performed on non-overlapped frames. From this parameterization, a reduced set of real parameters is obtained frame-to-frame. These parameters feed a classifier that performs a classification in three stages: inspiration, transition or retention and expiration providing a fine monitoring of the respiration process. As all of those algorithms are of low complexity and the auxiliary equipment required could only be a standard microphone from a conventional Bluetooth Headset, the system could be able to run in a smartphone device. © 2013 Springer-Verlag Berlin Heidelberg.ca_ES
dc.formatapplication/pdf
dc.format.extent8 p.ca_ES
dc.language.isoengca_ES
dc.publisherSpringerca_ES
dc.rights(c) Springer (The original publication is available at www.springerlink.com)
dc.rightsTots els drets reservatsca_ES
dc.subject.otherRespiracióca_ES
dc.subject.otherDispositius mòbils
dc.titleTowards a low-complex breathing monitoring system based on acoustic signalsca_ES
dc.typeinfo:eu-repo/semantics/conferenceObjectca_ES
dc.identifier.doihttps://doi.org/10.1007/978-3-642-38847-7-17
dc.relation.publisherversionhttp://link.springer.com/chapter/10.1007/978-3-642-38847-7_17
dc.rights.accessRightsinfo:eu-repo/semantics/closedAccessca_ES


Fitxers en aquest element

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Comparteix a TwitterComparteix a LinkedinComparteix a FacebookComparteix a TelegramComparteix a WhatsappImprimeix