Mostra el registre parcial de l'element
Heart rate deflection point relates to second ventilatory threshold in a tennis test
dc.contributor | Universitat de Vic. Facultat d'Educació, Traducció i Ciències Humanes | |
dc.contributor.author | Baiget i Vidal, Ernest | |
dc.contributor.author | Fernandez-Fernandez, Jaime | |
dc.contributor.author | Iglesias i Reig, Xavier | |
dc.contributor.author | Rodríguez, Ferran A. | |
dc.date.accessioned | 2015-03-20T11:56:21Z | |
dc.date.available | 2015-03-20T11:56:21Z | |
dc.date.created | 2015 | |
dc.date.issued | 2015 | |
dc.identifier.citation | Baiget Vidal, E., Fernández-Fernández, J., Iglesias, X., & Rodríguez, F. A. (2015). Heart rate deflection point relates to second ventilatory threshold in a tennis test. Journal of Strength and Conditioning Research, 29(3), 765-771. | ca_ES |
dc.identifier.issn | 1064-8011 | |
dc.identifier.uri | http://hdl.handle.net/10854/3941 | |
dc.description.abstract | The relationship between heart rate deflection point (HRDP) and the second ventilatory threshold (VT2) has been studied in continuous sports, but never in a tennis-specific test. The aim of the study was to assess the relationships between HRDP and the VT2, and between themaximal test performance and the maximal oxygen uptake (V_ O2max) in an on-court specific endurance tennis test. Thirty-five high-level tennis players performed a progressive tennis-specific field test to exhaustion to determine HRDP, VT2, and V_ O2max. Ventilatory gas exchange parameters were continuously recorded by a portable telemetric breath-by-breath gas exchange measurement system. Heart rate deflection point was identified at the point at which the slope values of the linear portion of the time/heart rate (HR) relationship began to decline and was successfully determined in 91.4% of the players. High correlations (r = 0.79–0.96; p , 0.001) between physiological (HR and oxygen uptake [V_ O2]) and performance (Time, Stage, and Frequency of balls [Ballf]) variables corresponding to HRDP and VT2 were observed. Frequency of balls at the HRDP (BallfHRDP) was detected at 19.8 6 1.7 shots per minute. Paired t-test showed no significant differences in HR (178.9 6 8.5 vs. 177.9 6 8.7 b$min21 for HRDP vs. HRVT2, respectively) at intensities corresponding to HRDP and VT2. Maximal test performance and V_ O2max were moderately correlated (r = 0.56; p , 0.001). Heart rate deflection point obtained from this specific tennis test can be used to determine the VT2, and the BallfHRDP can be used as a practical performance variable to prescribe on-court specific aerobic training at or near VT2. | en |
dc.format | application/pdf | |
dc.format.extent | 7 p. | ca_ES |
dc.language.iso | eng | ca_ES |
dc.publisher | Lippincott Williams & Wilkins | ca_ES |
dc.rights | (c) Lippincott Williams & Wilkins | |
dc.rights | Tots els drets reservats | ca_ES |
dc.subject.other | Tennis | ca_ES |
dc.title | Heart rate deflection point relates to second ventilatory threshold in a tennis test | en |
dc.type | info:eu-repo/semantics/article | ca_ES |
dc.identifier.doi | https://doi.org/10.1519/JSC.0000000000000664 | |
dc.rights.accessRights | info:eu-repo/semantics/closedAccess | ca_ES |
dc.type.version | info:eu-repo/publishedVersion | ca_ES |
dc.indexacio | Indexat a SCOPUS | |
dc.indexacio | Indexat a WOS/JCR | ca_ES |
Fitxers en aquest element
Aquest element apareix en la col·lecció o col·leccions següent(s)
-
Articles [1.395]